- May 18, 2021
-
-
Julian Dieskau authored
If I see it right there could be a segmentation fault if used in echo mode. When you choose echo mode the variable message wouldn't a value assigned and in the cleanup function the not allocated memory would be free'ed.
-
- Apr 04, 2021
-
-
Julian Dieskau authored
-
- Mar 29, 2021
-
-
Jonas Höppner authored
Option -c enables flowcontrol with rts and cts, for none RS485 mode. Option -t adds a delay after the reception of the first byte, usable to test the flowcontrol.
-
- Feb 18, 2021
-
-
Jonas Höppner authored
rand was initialized with time(0) which led to the same data if started twice in the same wall time second. Now also taking nanoseconds into acount. BCS 746-000172
-
- Nov 23, 2020
-
-
Clemens Terasa authored
The ```gettimeofday()``` function is defined in ```sys/time.h```. Thus include it. BCS 746-000125
-
- Nov 19, 2020
-
-
Jonas Höppner authored
* Add RS485 echo test for our EMC verification. * The test is more flexible than the legacy RS485 ping pong test and will always recover from transmission errors due to EMI. * The sent data includes a hard-coded 4-byte header and a 4-byte data length field, which is parsed by the receiver. The receiver always scans the received data for the header bytes in order to detect a new message. BCS 746-000125
-